Skip to content
sensidyne
800-451-9444 | +1 727-530-3602
  • Products
  • Applications
  • Service
  • Support
  • About us
  • Shop
  • Contact
  • Products
  • Applications
  • Service
  • Support
  • About us
  • Shop
  • Contact
  • PRODUCTS
  • APPLICATIONS
  • SERVICE
  • SUPPORT
  • ABOUT US
  • SHOP
  • CONTACT
  • Gilian Air Sampling
    • Gilian Dustlight
    • Gilian Silica Kits
    • GilAir Plus
    • Gilian 800i
    • Gilian 5000
    • Gilian 10i
    • Gilian 12
    • GilAir-3
    • GilAir-5
    • Gilian BDX-II
    • Gilian LFS-113
    • Gilian AirCon-2
    • Air Flow Calibrators
    • GilCARE Service Programs
  • Fixed Point Gas & Flame
    • SensAlarm Flex All-in-1
    • SensConnect Monitoring
    • SensAlert ASI
    • Plus Series Sensors
    • SensAlert IR
    • SensAir
    • SensFlex
    • SensCast Wireless
    • Sample Draw System
    • Gas Detection Controllers
    • Fire & Flame Detectors
    • Open Path Gas Detection
  • Gas Detector Tube Systems
  • OEM Micro / Miniature Pumps

Sensidyne / Fixed Gas / Hydrogen (H2) Combustible Gas Explosion Risks in Battery Back-up Rooms

Hydrogen (H2) Combustible Gas Explosion Risks in Battery Back-up Rooms

Combustible Hydrogen (H2) Gas Detectors for Battery Rooms
applications

Experts in Hydrogen (H2) Gas Detection

Battery Room Hydrogen Detection

Battery room safeguards are not generally well understood and yet as UPS systems see much more common use in data centers and Telcom, proper design, ventilation and other safeguards must be incorporated for safety, reliability and loss prevention. This discussion centers primarily on Hydrogen detection and ventilation, however the codes and standards are cited for more complete information. Hydrogen is produced during battery charging, which is a constant phenomena unless there is a power outage. The Uniform Fire Code and the International Fire Code and others permit Hydrogen levels as high as 1% by volume or 25% of the lower explosion limit.

Hydrogen has a wide flammability range (4% to 74% by volume), detonates (explodes) from 18% to 59%, and is very easily ignited. It burns with a pale blue, almost invisible flame, and can cause serious injury to personnel and severe equipment damage. Continuous ventilation can be employed in a battery room and the fan capacity should be at least the room area in square feet expressed as cubic feet per minute. One standard lists 12 air changes per hour and another 1 CFM capacity per charging ampere but not less than 6 air changes per hour. These ventilation standards apply only to ventilated batteries.

In common practice, one or more Hydrogen sensors are ceiling mounted and either turn-on or modulate a ventilation fan.  The gas detection panel usually combines annunciation outside the door and supervisory notification for the accepted solution in compliance with the codes and standards. In high value data centers with large UPS systems, an optical flame detector may be used to detect fire. This is advisable as Hydrogen flames are pale blue and nearly invisible. Fire damage and power outage is extremely costly.

Download the Sensidyne Battery Back-up Application Note using the link below:

Battery Back-up Room Application Note

 

 

NFPA 76, Standard for the Fire Protection of Telecommunications Facilities 2009 Edition
OSHA 29 CFR 1926.441, Battery Rooms and Battery Charging
EN 50272-2 Safety requirements for Secondary Batteries and Battery Installations
NFPA 111: Standard on Stored Electrical Energy Emergency and Standby Power Systems, 2005
NFPA 111: Standard on Stored Electrical Energy Emergency and Standby Power Systems, 2005
Alarm notification to a remote location, manned 24/7/365 and capable of response

Fixed Point Gas Detectors for Hydrogen (H2) Combustible Gas Explosion Risks in Battery Back-up Rooms

SensAlert ASI Fixed Point Gas Detector

Advanced Safety Integrity, SIL-2 Certified, Intrinsically Safe– 2-4 weeks lead time.

Gas Detection Sample Draw System

SensAlarm FLEX All-in-One Gas Detection

Turn-Key Solution for Critical Safety Applications – with HazLoc Certification!

Application support

Need support with an application or a product quote?


Click the button below and our team would be more than happy to assist.

Request a Quote or Support
Products
  • Gilian Air Sampling
  • Fixed Point Gas Detection Systems
  • Fixed Point Fire & Flame Detection
  • Colorimetric Gas Detector Tube Systems
  • OEM Micro / Miniature Air Pumps
About us
  • News & Events
  • Careers
  • Global Sales Partners
  • Shop
  • Certifications
  • Terms and Conditions
Support
  • Technical & Support Library
  • Technical Software
  • Quality & Regulatory Certification
  • Certified Factory Service
Contact
  • Request a Quote or Support Form
  • 800-451-9444
  • +1 727-530-3602
  • Sensidyne, LP
    1000 112th
    Circle North, Suite 100
    St. Petersburg, FL 33716 U.S.A.
Newsletter Join our mailing list
Subscribe

Terms and Conditions

sensidyne

© 2025 Sensidyne, LP. All rights reserved.

sensidyne
Get the Full Application Guide
Get complete access to our technical materials and case studies. 
 Fill out the form to download the full guide in PDF and keep it handy for your team.

    Enter your details
    I have read and agree to the Terms and Conditions
    sensidyne

    Get the latest news straight to your inbox

    Join our subscribers list to get the latest news, updates and special offers delivered directly in your inbox

      Enter your personal details
      Areas of interest:
      Gilian Air SamplingFixed Point Gas Detection SystemsGas Detector Tube SystemsOEM Micro / Miniature Air PumpsHeat Stress Monitors